| FEATURES | VALUES/ STANDARDS |
|---|---|
| Ambient Temperature | -10 to +50°C |
| Altitude | Not exceeding 1000mtrs above mean sea level. |
| Atmosphere | Non Corrosive & non Hazardous |
| Relative Humidity | Up to 100% |
| Voltage | 415V ±10%, 3 ph. |
| Frequency | 50Hz ±5% |
| Combined Variation | 10% |
| Duty | S1 (continuous) |
| Service factor | 1.0 |
| FEATURES | VALUES/ STANDARDS |
|---|---|
| Starting | Resistive start |
| Permissible starts/hr | Cold successive – 4 , Hot successive - 3, Equally spread - 6 |
| Loading at reduced volts | 75% Rated volts for 5 minutes |
| Insulation ST / RT | Class `F' / 'F' |
| Temp. Rise ST / RT | Class `B' / 'F' |
| Direction of rotation | Bi-directional |
| No. Of leads, ST/RT | 3 / 3 |
| Degree of protection | IP 55 |
| Method of cooling | IC 411 |
| T.box position | RHS looking from DE |
| Bearing life (90 % survival basis) |
40,000 working hrs. For direct drive 20,000 working hrs. For belt drive |
| Vibration | Normal class as per IS 12075. |
| Noise | As per IS 12065 |
| Construction | Foot mounted |
| Frame sizes | SD 180L, SD200L , SD225M , SD250S & M, SD280S & M, SD315, SD315LX & SDX355X |
| Shaft extension | Single cylindrical extension as per IS 1231 |
| Body material | Cast iron |
| T.box material | Cast iron up to 225 Frames, mild steel for 250 to 355 Frames |
| Fan material | Cast iron up to 225 Frames, mild steel for 250 to 355 Frames |
| Accessories |
Nil |
| Paint & shade | NC base RAL5012 shade up to 225, Epoxy base RAL5012 above 225 |
| Bearing type Greasing facility |
Open type ball bearings for all frames Online greasing facility is for all frames |
| FRAME | FOOT | MAX. CABLE SIZE, STATOR |
|---|---|---|
| 180L | 32217797 | 1x3.5Cx70sqmm |
| 200L | ||
| 225M | ||
| 250M | 31108697 | 1x3Cx120sqmm |
| 280S & M | 1x3Cx185sqmm | |
| 315 | 31100897 | MMD-02-150 |
| 315LX | 31111103 | |
| 355X | 31102906 |