FEATURES | VALUES/ STANDARDS |
Starting |
Stator Rotor Starter/Liquid Rotor Starter |
Permissible starts/hr. |
2 Hot Or 3 Cold or 4 Equally spread |
Loading at reduced volts |
These motors are designed to run at 75% of rated supply voltage for a duration of five minutes. |
Insulation / temp.rise |
Class F/F |
Temp rise Stator/Rotor |
Class B/F |
Direction of rotation |
Bi-directional |
No. Of leads |
TR 5&6 > ST: 6 and RT: 3 Rest 3 / 3 |
Degree of protection |
IP23 |
Method of cooling |
IC01 |
T.box position |
Left hand side when viewed from non-drive end, reversible assembly at site is not possible. |
Terminal box arrangement |
For KCW 450 & 500: Stator – 43506201, Rotor – 43521599. For KCW 560: Stator – 41102205, Rotor – 43506101. Terminal box rotatable through 3600 in steps of 180° (i.e cable entry possible from top or buttom) |
Bearing life(90% survival basis) |
Lithium based grease to "Grade 3" as per IS: 7623 for 4 pole & above motors. |
Lubricant |
Direct drives: 40,000 working hours.(Based on 90% survival life) |
Vibration |
Normal class as per IS: 12075. |
Noise |
As per IS: 12065. |
Shaft extension. |
Single cylindrical extension as per IS: 1231. |
Body material |
Mild Steel |
T.box material |
Mild Steel |
Fan material |
Mild Steel |
Accessories |
Refer to Kirloskar Electric engineering department. |
Paint & shade |
Epoxy "RAL BLUE" to shade plate K-102 |
Bearing type and Greasing facility |
Antifriction rolling contact (Ball & Roller) Online greasing facility for all frames |